Mounts |
Ground Fault Protectors |
Breakers |
Fuses & Fuse Holders |
Terminal Bus Bars |
Mounts
| Dual Backplate 16 gauge gray steel accepts one or two EPanels, (wide or narrow). Wires route behind the 2” thick plate for a clean installation. Rear cover plates enclose wires from mounting surface. Shipping: 48” x 31” x 3” 25 Lb. |
Ground Fault Protectors
![]() |
MNDC-GFP 63 amp 150VDC DC ground fault protector (UL listed breaker assy). NEC2008 requires DC-GFP’s in ALL solar installations Shipping: 2 Lb. |
| MNDC-GFP80 80 amp 125VDC DC ground fault protector (UL listed breaker assy) ½ amp trip mechanism connects between battery negative and earth ground NEC2008 requires DC-GFP’s in ALL solar installations Shipping: 2 Lb. |
Breakers
| MNEAC20-2P 20 amp 120/240 VAC UL489 two pole Shipping: 26mm wide - 2 Lbs. |
|
| MNEAC50-2P Shipping: 26mm wide - 2 Lbs. |
|
| MNEAC15QZD, MNEAC30QZD, MNEAC50QZD White 15, 30 or 50 amp 277VAC UL1077 single pole |
|
| MNEAC30QZD2P, MNEAC50QZD2P, MNEAC60QZD2P White 30, 50 or 60 amp 277VAC UL1077 double pole |
|
| MNEAC30QZD3P, MNEAC50QZD3P White or black 30 or 50 amp 277VAC UL1077 triple pole. Shipping: 1.5” wide |
|
| MNEPV 150VDC din rail mount breaker 1,2,3,4,5,6,7,8,9,10,12,15,20,30,40,50,63 amps MNEPV breakers 150VDC ETL listed in the US and Canada Shipping: 13mm wide 1 Lb |
|
| MNEPV07-300, MNEPV10-300, MNEPV12-300, MNEPV15-300, MNEPV20-300, MNEPV30-300 7, 10, 12, 15, 20 or 30 amp 300VDC UL489 listed din rail mount breaker. Shipping: 2 Lbs. |
|
![]() |
MNEPV50-300 High voltage breaker 50 amp 300VDC UL489 listed din rail mount breaker. This is the first in a series of breakers that is necessary for 300 volt charge controllers. NOTE: 300 VDC listing is pending. Shipping: 2 Lb. |
| MNEAC10, 15, 20 15-60 amp 120VAC UL489A din rail mount. Shipping: 13mm wide 1 Lb NOTES: Note: UL489A is the branch circuit rating, UL1077 is for supplementary protection |
|
| MNEAC30, 40, 50, 60 15-60 amp 120VAC UL1077 din rail mount Shipping: 13mm wide 1 Lb NOTES: Note: UL489A is the branch circuit rating, UL1077 is for supplementary protection |
|
| MNEDC60, MNEDC70, MNEDC80, MNEDC90, MNEDC100 60, 70, 80, 90 or 100 amp 125VDC Panel Mount. Shipping: ¼ studs / ¾ wide 1 Lb. |
|
| MNEDC175 & MNEDC250 125VDC 3/8” studs 1.5” Shipping: 3 Lbs |
Fuses & Fuse Holders
| MNTS Touch Safe Fuse Holder for10x38 mm fuses 600VDC 30 amp Din rail mount Use in the MNPV combiners for high voltage string inverters. Shipping: 1 Lb. |
|
| MNTS2 POLE Double ganged 2 pole Touch safe fuse holder for 10 x 38mm fuses. This fuse holder is used for transformer less grid tie inverter arrays. One pole is plus VDC and the other is minus VDC. The MNPV combiners do not yet accommodate this fuse holder. Shipping: 1 Lb. |
|
![]() |
MNFUSE01, MNFUSE04, MNFUSE06, MNFUSE08, MNFUSE10, MNFUSE12, MNFUSE15, MNFUSE20, MNFUSE30 1, 4, 6, 8, 10, 12, 15, 20, 30 amp 1000VDC, goes with MNTS fuse holder. Shipping: 1 Lb. |
Terminal Bus Bar
| MNTBR (Red), MNTBW (White), MNTBB (Black) Four 1/0 & eleven #6 useable wire slots. Comes with 10-32 screws. |
|
| MNTBB-NAKED Same as above but without insulators. Comes with 10-32 screws. Bus Bar 4.63” UL and CSA recognized, Made in USA. Insulators ETL recognized, Designed by MidNite Solar and Made in China 1Lb. Remove the plastic insulators for ground bus applications. A dimensioned drawing is on the MidNite website as “Long MNTB Dimensions” |
|
| MNSBBR, MNSBBB, MNSBBW (Midnite Short Busbar) Shorter version of the insulated bus bars above. These are useful for PV+ input on the narrow OB E-Panel and for a separate PV- bus bar for charge controllers that require them. Four #6 and two 1/0 wire slots. A dimensioned drawing is on the MidNite website as “Short MNTB Dimensions” Shipping: 1 Lb. |
|
| MNSBBN 2.3” long. Two 1/0 & four #6 wire slots. Comes with mounting screw& nut #10-32 x 7/8”. Made in USA, UL and CSA recognized. Shipping: 1 Lb |
|
| MNGBB 3.45” long with Green screws! Two 1/0 & seven #6 wire slots. Comes with mounting screws. Made in USA, UL and CSA recognized. Shipping: 1 Lb |
|
| MNPV6 MNPV6 BUSBAR This .093” thick copper bus has six fingers spaced at ½” (13mm) intervals Two box lugs are provided to accommodate 14-1/0 AWG wire. Shipping: 1 Lb. |
|
| MNPV6 FUSE BUSBAR This .063” thick copper bus has four fingers spaced at ¾” (19mm) intervals One box lug is provided that accommodates 14-1/0 AWG wire. Shipping: 1 Lb. |
|
| MNPV3 BUSBAR This .093” thick copper bus has three fingers spaced at ½” (13mm) intervals one box lug is provided to accommodate 14-1/0 AWG wire. Shipping: 1 Lb. |
|
| BIG BUSBAR PLUS or MINUS 280 amps, Same busbar used in the Nottagutter. Five battery connections. Comes with auxiliary terminal busbar for six small wires #14-1/0. Shipping: 1 Lb. |
|
| BIG BREAKER BUS 8 studs for multiple paralleled battery strings. Shipping: 2 Lbs. |
|
| SHUNT BUSBAR Mounts on 500 shunt. Same busbar used in the Nottagutter. Four battery cable studs and six position aux terminal busbar. Shunt sold separately. Shipping: 1 Lb. |
|
| TIN PLATED COPPER PLATE (MNBP-SHUNT/BREAKER) 063” x 2.1” x 1.5” One 3/8”, five .250, two .203” holes. Used on MNDC shunts for an additional bat minus connections. Shipping: 1 Lb |
|
| SHUNT 500amp/50mV includes taptite mounting screws. Has two 8-32 tapped holes on one end to attach a bus bar. This is the industry standard shunt. Shipping: 2 Lbs. |
|
| SHUNT WIRE Shunt wire 36 inches long. Two twisted pair, one red& black, one blue & white Includes two ring terminals. Bogart Engineering recommends twisted wire. Shipping: 1 Lb. NOTES: Order the MNEPV2 2 amp breaker, shunt and wire to hook up the Trimetric to a MNDC175 or 250 |
|
| SIDE PLATE ALL DIN RAIL KNOCK OUTS 120 CHASSIS Aluminum or steel Shipping: 2 Lbs. |
|
| SIDE PLATE DUAL SLIDER 120 CHASSIS Gray steel, ships with two single pole sliders not shown. Shipping: 2 Lbs. |
|
| SIDE PLATE DUAL SLIDER 240 CHASSIS White steel, ships with two pole sliders not shown Shipping: 2 Lbs. |
| Back to Balance of System |